Tri-Tek Electronics  
Fluke SureGrip Temperature Accessory Chart
 
Home

SureGrip Tempurature Accessories


The innovative SureGrip design from Fluke is now available in select temperature probes. The soft rubber handle combined with a new ergonomic shape is so comfortable to hold that you'll forget about the probe and focus on the measurement. All SureGrip probes have an improved, more flexible strain relief for a long life.

The 80PJ-EXT, 80PK-EXT, and 80PT-EXT are 3 meter J, K, and T (respectively) type extension thermocouple wire with male/female mini-connectors.

  Bead Bead Immersion Surface Air Piercing General
Purpose
Industrial
Surface
Pipe
Clamp
HVAC
Click Picture for larger view.
Click Name
to buy.
80BK 80PK-1
80PJ-1
80PK-22 80PK-3A 80PK-24 80PK-25
80PT-25
80PK-26 80PK-27 80PK-8 80PK-9
80PJ-9
Lowest
Temp
-40oC,-40oF -40oC,-40oF -40oC,-40oF 0oC, 32oF -40oC,-40oF K-Type:
-40oC,-40oF
T Type:
-196oC,-321oF
-40oC,-40oF -127oC,-196oF -29oC,-20oF -40oC,-40oF
Highest
Temp
260oC,500oF 260oC,500oF 1090oC,1994oF 260oC,500oF 816oC,1500oF 350oC,662oF 816oC,1500oF 600oC,1112oF 149oC,300oF 260oC,500oF
Probe
Material
K type wire with teflon insulation K type wire with teflon insulation Inconel 600 K type sensor with teflon insulation Inconel 316 Stainless Steel 304 Stainless Steel 304 Stainless Steel K type sensor with pvc body 304 Stainless Steel
Cable
Length
1m lead wire 1m lead wire 21.27 cm
8.375 in
9.525 cm
3.75 in
21.59 cm
8.5 in
10.16 cm
4 in
21.57 cm
8.5 in
20.32 cm
8 in
for pipes from 6.4mm (.25in) to 34.9mm(1.375in) 15.25 cm
6 in
Connection Standard Banana Jack Molded Thermocouple Plug Molded Thermocouple Plug Molded Thermocouple Plug Molded Thermocouple Plug Molded Thermocouple Plug Molded Thermocouple Plug Molded Thermocouple Plug Molded Thermocouple Plug Molded Thermocouple Plug
SureGrip
Handle
No No Yes No Yes Yes Yes Yes No No
Key
Feature
Ideal for initial troubleshooting. Can be secured in place with a magnet. Ideal for initial troubleshooting. Can be secured in place with a magnet. For use in liquids or in gels. Exposed junction for direct contact with flat or slightly convex surfaces. Perforated baffle for air and non-caustic gas measurements. Probe material safe for use in foods. Sharp tip pierces solid surfaces. Use for general purpose air or surface measurements Low conductivity stainless steel minimizes thermal shunting. Extra rugged. Clamps securely to pipe. Measurements are repeatable to 0.56oC(1oF) Sharp tip pierces pipe insulation, flat surface makes good contact with surface.
Thermocouple
Types
K K, J K K K K, T K K K K, J
Typical Use
General
Purpose
X X X X X X X X X X
HVAC   X X X X   X X X X
Food
Service
    X     X        
Industrial X X           X X X
Residential X X   X X X     X  
Commercial X X X X X X X X X X
 
Checkout
Advanced Search
Sign In

  Search:
  Search  

 
 
 Shopping Cart:
 0 Items In Cart
 Total: $0.00